Products » Cooling systems » Power unit for EXPO 2000

Power unit for EXPO 2000 in Hannover

 

Technical specificationstl_files/images/unternehmen/frauenkirche.jpg
  • Installed load: 18,5 kW
  • RPM: 1500 RPM:
  • Noise level: 78 dB(A)
  • Type of oil: ISO VG 46
  • Delivery rate: 120 l/min
  • Operating pressure: 3-120 bar
  • Pump protection: 150 bar

Depending on light and music effects, four 3-stage synchronized telescoping cylinders are synchronized and operated by means of 4 servo valves. The stroke height for this application is 2800 mm and the load per cylinder is 4 t.